About 50 results
Open links in new tab
  1. Is a Specific Type of Separation Required Between a Private Garage and ...

    Oct 16, 2009 · If the garage is located beneath any habitable space, the separation requirements are more stringent, necessitating the use of 5/8-inch (15.9 mm) Type X gypsum board or a material that …

  2. S-1 & S-2 Regarding Parking Garage - The Building Code Forum

    Jan 7, 2015 · Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage". Section 311.3 Classifies "Parking garages, open or …

  3. Garage pedestrian door size | Building Code Forum: Construction ...

    Nov 24, 2025 · I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door. will that size be acceptable since it is not the main egress door?

  4. HVAC in a garage - The Building Code Forum

    Jan 12, 2012 · The leakage around a garage door and the cubic volume of a double car garage should provide an adquate supply of combustion air to any "B" vented unit. We have encouraged CO …

  5. Branch Circuit to Detached Garage - The Building Code Forum

    Oct 16, 2009 · An electrical service disconnect is located in or on the main structure. One of the panelboard has a 20A GFCI breaker that is labeled "garage." The garage is detached and the circuit …

  6. Egress Door From Garage | Building Code Forum: Construction

    Oct 16, 2009 · My attached garage has a man door, and my detached garage has a man door. On the other hand, under the IBC an overhead garage door is allowed to be used as a required exit door for …

  7. Egress through a garage. - The Building Code Forum

    Apr 9, 2015 · A detached garage is not going to require egress in the same manner as a habitable space. How do you egress out of a garage itself? Good question. A detached garage as i understand …

  8. Garage Open Air Calculations - The Building Code Forum

    Dec 18, 2011 · I am designing a garage, and trying to achieve natural ventilation. I think I have achieved the required 20% open, as well as 40% perimeter open as per IBC 2006, but what if your garage is …

  9. NC Garage Legal Finish Requirement | Building Code Forum: …

    Jan 29, 2024 · The garage is 100% residential- not a business. The first floor has lights & outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added …

  10. Door size from house to garage | Building Code Forum: Construction ...

    Aug 17, 2020 · I'm new to this forum, but not new to the headache of trying to find code find & what will pass inspection for my Remodel. I currently have no door from house into the garage. I asked the …